NAFDAC Reg. No. A3-101202 · Drug
About the medicine: Analyzer: uses, dosage and brands worldwide
Generated automatically from the NAFDAC register, WHO alerts and community data as of today. This is not medical advice. Always follow your doctor or pharmacist.
What the official label says. If a doctor prescribed it, follow the prescription. Your pack's leaflet comes first if it is different.
REBINYN, Coagulation Factor IX (Recombinant), GlycoPEGylated, is a recombinant DNA-derived coagulation Factor IX concentrate indicated for use in adults and children with hemophilia B (congenital Factor IX deficiency) for: • On-demand treatment and control of bleeding episodes • Perioperative management of bleeding • Routine prophylaxis to reduce the frequency of bleeding episodes Limitations of Use : REBINYN is not indicated for immune tolerance induction in patients with hemophilia B. …
REBINYN is available as a white to off-white lyophilized powder in single-dose vials containing nominally 500, 1000, 2000, or 3000 IU per vial. Each carton and vial label for REBINYN states the actual Factor IX potency in IU. After reconstitution with 4 mL of histidine diluent, the reconstituted solution contains approximately 125, 250, 500, or 750 IU per mL of REBINYN respectively. …
Clinical studies of REBINYN did not include sufficient numbers of subjects age 65 and over to determine whether or not they respond differently than younger subjects. Animals administered repeat doses of REBINYN showed accumulation of PEG in the choroid plexus, pituitary, circumventricular organs, and cranial motor neurons. [ see Use in Specific Populations ( 8.4 ) and Animal Toxicology and/or Pharmacology ( 13.2 ) ]. …
REBINYN is contraindicated in patients who have known hypersensitivity to REBINYN or its components (including hamster proteins) [ see Warnings and Precautions ( 5.1 ) and Description ( 11 ) ] Do not use in patients who have known hypersensitivity to REBINYN or its components, including hamster proteins ( 4 ).
• Hypersensitivity reactions, including anaphylaxis, have occurred. Should hypersensitivity reactions occur, discontinue REBINYN and administer appropriate treatment ( 5.1 ). • Neutralizing antibodies (inhibitors) to Factor IX have occurred following administration of REBINYN. Perform an assay that measures Factor IX inhibitor concentration if bleeding is not controlled with the recommended dose of REBINYN or if plasma Factor IX activity level fails to increase as expected (5.2 , 5.5 ). • The use of Factor IX- products has been associated with the development of thromboembolic complications ( 5.3 ). …
Common adverse reactions (incidence ≥ 1%) in PTPs reported in clinical trials for REBINYN were itching and injection site reactions. Common adverse reactions (incidence ≥ 1%) in PUPs reported in clinical trials for REBINYN were rash, FIX inhibitors, hypersensitivity, itching, injection site reaction, and anaphylactic reaction. The most frequently reported adverse reactions (≥ 1%) in previously treated patients (PTPs) and previously untreated patients (PUPs) were itching and injection site reactions ( 6 ). Additional frequently reported adverse reactions (≥ 1%) in PUPs included rash, Factor IX inhibition, hypersensitivity, and anaphylactic reaction ( 6 ). …
8.1 Pregnancy Risk Summary There are no data with REBINYN use in pregnant women to determine whether there is a drug-associated risk. Animal reproduction studies have not been conducted with REBINYN. It is unknown whether REBINYN can cause fetal harm when administered to a pregnant woman or can affect fertility. In the U.S. …
Take it when you remember, unless it is nearly time for the next dose. Then skip the missed one. Never take two doses at once to make up for it. Check your leaflet, as some medicines are different.
Label for Cobas T711 Coagulation Analyzer, the active ingredient registered with NAFDAC.
Add the expiry date on your pack for a full Trust Score.
Cobas T711 Coagulation Analyzer contains Analyzer (NA), as na, according to its NAFDAC registration record.
Yes. Cobas T711 Coagulation Analyzer is listed on the NAFDAC register under registration number A3-101202, and its registration is active as of 31 October 2026.
No WHO falsified or substandard medical product alert currently matches Cobas T711 Coagulation Analyzer in our automatically synced alert list.
Run a free authenticity scan with the NAFDAC number A3-101202, your pack's expiry date and batch number to get a Trust Score, compare the pack with the NAFDAC record (ingredient, strength, form, manufacturer), and buy only from licensed pharmacies.
Follow your prescription or the leaflet in your pack. The official label says: For intravenous infusion after reconstitution only. For intravenous infusion after reconstitution only ( 2 ). • Each carton and vial label for REBINYN states the actual Factor IX potency in international units (IU) ( 2.1 ). On-demand treatment and control of bleeding episodes: • 40 IU/kg body weight for minor and moderate bleeds, and 80 IU/kg body weight for major bleeds. Addit…
REBINYN, Coagulation Factor IX (Recombinant), GlycoPEGylated, is a recombinant DNA-derived coagulation Factor IX concentrate indicated for use in adults and children with hemophilia B (congenital Factor IX deficiency) for: • On-demand treatment and control of bleeding episodes • Perioperative management of bleeding • Routine prophylaxis to reduce the frequency of bleeding episodes Limitations of U (Summarised from the official U.S. FDA label for Cobas T711 Coagulation Analyzer. Always follow your doctor or pharmacist.)
Reviews are personal experiences from PillVera users, not medical advice. Report side effects to your doctor and to NAFDAC.